Detailed Description
Type |
Max.Production Size |
Min.Production Size |
Thickness Range |
OutputHour(5mm white glass) |
Transformer Capacity |
SC-E1020 |
1000*2000 |
100*100 |
2.85-19 |
26m²/h |
250KVA |
SC-E1425 |
1400*2500 |
300*100 |
2.85-19 |
45m²/h |
250KVA |
SC-E1825 |
1800*2500 |
300*100 |
4-19 |
58m²/h |
250KVA |
SC-E2030 |
2000*3000 |
300*100 |
4-19 |
77m²/h |
400KVA |
SC-E2436 |
2440*3600 |
300*150 |
4-19 |
106m²/h |
500KVA |
SC-E2442 |
2440*4200 |
300*150 |
4-19 |
121m²/h |
630KVA |
SC-E2842 |
2800*4200 |
300*200 |
4-19 |
150m²/h |
800KVA |
SC-E2450 |
2440*5000 |
300*150 |
4-19 |
144m²/h |
800KVA |
SC-E2850 |
2800*5000 |
300*200 |
4-19 |
179m²/h |
800KVA |
SC-E2860 |
2800*6000 |
300*200 |
4-19 |
215m²/h |
1000KVA |
SC-E3360 |
3300*6000 |
300*200 |
5-19 |
253m²/h |
1000KVA |
SC-E3380 |
3300*8000 |
300*200 |
5-19 |
338m²/h |
1250KVA |
1、Heating wires control mode adopts PLD closed-loop control, which makes heating system intelligent flexibility.
2、Heating control mode adopts multiple temperature control curves, which makes different glass sizes can enter into one furnace for heatingsimultaneously, while the quality can reach the best.
3、Heating mode adopts intelligent protection measures, which avoids scalding glass surface caused by furnace temperature out of control.
4、Frequency conversion blower used for stepless speed regulation, thus maximizes the energy savings.
5、Emergency DC protection system is used to prevent glass damaging quartz roller caused by power off.
6、Hundreds of operating parameters can be stored in the control system, and the appropriate production process parameters can be adjusted at any time according to the production situation.
7、The temperature control of the control system adopts the dual protection of time and temperature, which absolutely avoids the phenomenon of glass sticking quartz roller.
8、The automatic function of timed temperature rise up can set up the automatic heating in unmanned mode at any time.
9、Power failure warning system will make automatic alarm and telephone notification incase of power failure at any time.